ASoC: tas2781: Fix a warning reported by robot kernel test
[ Upstream commit1ae14f3520
] Fix a warning reported by robot kernel test that 'fw_entry' in function 'tas2781_load_calibration' is used uninitialized with compiler sh4-linux-gcc (GCC) 13.2.0, an update of copyright and a correction of the comments. Fixes:ef3bcde75d
("ASoc: tas2781: Add tas2781 driver") Signed-off-by: Shenghao Ding <shenghao-ding@ti.com> Link: https://lore.kernel.org/r/20240505122346.1326-1-shenghao-ding@ti.com Signed-off-by: Mark Brown <broonie@kernel.org> Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
parent
a1955a6df9
commit
2d062f7468
|
@ -1,8 +1,8 @@
|
|||
// SPDX-License-Identifier: GPL-2.0
|
||||
//
|
||||
// tasdevice-fmw.c -- TASDEVICE firmware support
|
||||
// tas2781-fmwlib.c -- TASDEVICE firmware support
|
||||
//
|
||||
// Copyright 2023 Texas Instruments, Inc.
|
||||
// Copyright 2023 - 2024 Texas Instruments, Inc.
|
||||
//
|
||||
// Author: Shenghao Ding <shenghao-ding@ti.com>
|
||||
|
||||
|
@ -1908,7 +1908,7 @@ int tas2781_load_calibration(void *context, char *file_name,
|
|||
{
|
||||
struct tasdevice_priv *tas_priv = (struct tasdevice_priv *)context;
|
||||
struct tasdevice *tasdev = &(tas_priv->tasdevice[i]);
|
||||
const struct firmware *fw_entry;
|
||||
const struct firmware *fw_entry = NULL;
|
||||
struct tasdevice_fw *tas_fmw;
|
||||
struct firmware fmw;
|
||||
int offset = 0;
|
||||
|
|