mirror of
https://github.com/nxp-imx/linux-imx.git
synced 2025-07-07 09:55:19 +02:00
iio: pressure: bmp280: Fix waiting time for BMP3xx configuration
[ Upstream commit262a6634bc
] According to the datasheet, both pressure and temperature can go up to oversampling x32. With this option, the maximum measurement time is not 80ms (this is for press x32 and temp x2), but it is 130ms nominal (calculated from table 3.9.2) and since most of the maximum values are around +15%, it is configured to 150ms. Fixes:8d32930918
("iio: pressure: bmp280: Add support for BMP380 sensor family") Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com> Link: https://patch.msgid.link/20240711211558.106327-3-vassilisamir@gmail.com Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
parent
ae6724f9f1
commit
736da42408
|
@ -1203,10 +1203,11 @@ static int bmp380_chip_config(struct bmp280_data *data)
|
|||
}
|
||||
/*
|
||||
* Waits for measurement before checking configuration error
|
||||
* flag. Selected longest measure time indicated in
|
||||
* section 3.9.1 in the datasheet.
|
||||
* flag. Selected longest measurement time, calculated from
|
||||
* formula in datasheet section 3.9.2 with an offset of ~+15%
|
||||
* as it seen as well in table 3.9.1.
|
||||
*/
|
||||
msleep(80);
|
||||
msleep(150);
|
||||
|
||||
/* Check config error flag */
|
||||
ret = regmap_read(data->regmap, BMP380_REG_ERROR, &tmp);
|
||||
|
|
Loading…