![]() In 'lvts_should_update_thresh()' and 'lvts_ctrl_start()' functions,
the parameter passed to 'lvts_for_each_valid_sensor()' macro is always
'lvts_ctrl->lvts_data->lvts_ctrl'. In other words, the array index 0
is systematically passed as 'struct lvts_ctrl_data' type item, even
when another item should be consumed instead.
Hence, the 'valid_sensor_mask' value which is selected can be wrong
because unrelated to the 'struct lvts_ctrl_data' type item that should
be used. Hence, some thermal zone can be registered for a sensor 'i'
that does not actually exist. Because of the invalid address used
as 'lvts_sensor[i].msr', this situation ends up with a crash in
'lvts_get_temp()' function, where this 'msr' pointer is passed to
'readl_poll_timeout()' function. The following message is output:
"Unable to handle kernel NULL pointer dereference at virtual
address <msr>", with <msr> = 0.
This patch fixes the issue.