Remove IRQF_TRIGGER_FALLING flag from irq request, this should come from
the platform firmware and should not be hard-coded into the driver.
Add IRQF_ONESHOT flag to the irq request, the interrupt should not be
re-activated in interrupt context, it should be done only after the
device irq handler run.
Fixes: a9306887eb ("iio: adc: ti-ads1119: Add driver")
Signed-off-by: Francesco Dolcini <francesco.dolcini@toradex.com>
Reviwed-by: João Paulo Gonçalves <jpaulo.silvagoncalves@gmail.com>
Link: https://patch.msgid.link/20240731140657.88265-1-francesco@dolcini.it
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Use iio_get_masklength() to access '.masklength' so it can be annotated
as __private when there are no more direct users of it.
Signed-off-by: Nuno Sa <nuno.sa@analog.com>
Reviewed-by: João Paulo Gonçalves <jpaulo.silvagoncalves@gmail.com>
Link: https://patch.msgid.link/20240726-dev-iio-masklength-private3-v1-13-82913fc0fb87@analog.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The ADS1119 is a precision, 16-bit, analog-to-digital converter (ADC)
that features two differential or four single-ended inputs through a
flexible input multiplexer (MUX), rail-to-rail input
buffers, a programmable gain stage, a voltage reference, and an
oscillator.
Apart from normal single conversion, the driver also supports
continuous conversion mode using a triggered buffer. However, in this
mode only one channel can be scanned at a time.
Datasheet: https://www.ti.com/lit/gpn/ads1119
Signed-off-by: João Paulo Gonçalves <joao.goncalves@toradex.com>
Signed-off-by: Francesco Dolcini <francesco.dolcini@toradex.com>
Link: https://patch.msgid.link/20240617183905.4685-1-francesco@dolcini.it
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>