mirror of
git://git.yoctoproject.org/linux-yocto.git
synced 2025-10-22 23:13:01 +02:00

e-mail received from Silicon Lab to confirm that the licensing isn't a problem. " Dear Maxime Roussin-Belanger, The LUX calculation code only works with Si1133. As long as the software is used with Silicon Lab's sensor product, I don't see any problem. Regards, Tony " Signed-off-by: Maxime Roussin-Bélanger <maxime.roussinbelanger@gmail.com> Reviewed-by: Jean-Francois Dagenais <jeff.dagenais@gmail.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
729 B
729 B
What: /sys/bus/iio/devices/iio:deviceX/in_intensity_ir_small_raw KernelVersion: 4.18 Contact: linux-iio@vger.kernel.org Description: Unit-less infrared intensity. The intensity is measured from 1 dark photodiode. "small" indicate the surface area capturing infrared.
What: /sys/bus/iio/devices/iio:deviceX/in_intensity_ir_large_raw KernelVersion: 4.18 Contact: linux-iio@vger.kernel.org Description: Unit-less infrared intensity. The intensity is measured from 4 dark photodiodes. "large" indicate the surface area capturing infrared.
What: /sys/bus/iio/devices/iio:deviceX/in_intensity_large_raw KernelVersion: 4.18 Contact: linux-iio@vger.kernel.org Description: Unit-less light intensity with more diodes.