Introduces a more generalized ABI documentation for DAC. Instead of having separate ABI files for each DAC, we now have a single ABI file that covers the common sysfs interface for all DAC. Signed-off-by: Kim Seer Paller <kimseer.paller@analog.com> https://patch.msgid.link/20240718051834.32270-2-kimseer.paller@analog.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2.6 KiB
What: /sys/bus/iio/devices/iio:deviceX/out_currentY_toggle_en KernelVersion: 5.18 Contact: linux-iio@vger.kernel.org Description: Toggle enable. Write 1 to enable toggle or 0 to disable it. This is useful when one wants to change the DAC output codes. For autonomous toggling, the way it should be done is:
- disable toggle operation;
- change out_currentY_rawN, where N is the integer value of the symbol;
- enable toggle operation.
What: /sys/bus/iio/devices/iio:deviceX/out_currentY_rawN KernelVersion: 5.18 Contact: linux-iio@vger.kernel.org Description: This attribute has the same meaning as out_currentY_raw. It is specific to toggle enabled channels and refers to the DAC output code in INPUT_N (_rawN), where N is the integer value of the symbol. The same scale and offset as in out_currentY_raw applies.
What: /sys/bus/iio/devices/iio:deviceX/out_currentY_symbol KernelVersion: 5.18 Contact: linux-iio@vger.kernel.org Description: Performs a SW switch to a predefined output symbol. This attribute is specific to toggle enabled channels and allows switching between multiple predefined symbols. Each symbol corresponds to a different output, denoted as out_currentY_rawN, where N is the integer value of the symbol. Writing an integer value N will select out_currentY_rawN.
What: /sys/bus/iio/devices/iio:deviceX/out_voltageY_toggle_en KernelVersion: 5.18 Contact: linux-iio@vger.kernel.org Description: Toggle enable. Write 1 to enable toggle or 0 to disable it. This is useful when one wants to change the DAC output codes. For autonomous toggling, the way it should be done is:
- disable toggle operation;
- change out_voltageY_rawN, where N is the integer value of the symbol;
- enable toggle operation.
What: /sys/bus/iio/devices/iio:deviceX/out_voltageY_rawN KernelVersion: 5.18 Contact: linux-iio@vger.kernel.org Description: This attribute has the same meaning as out_currentY_raw. It is specific to toggle enabled channels and refers to the DAC output code in INPUT_N (_rawN), where N is the integer value of the symbol. The same scale and offset as in out_currentY_raw applies.
What: /sys/bus/iio/devices/iio:deviceX/out_voltageY_symbol KernelVersion: 5.18 Contact: linux-iio@vger.kernel.org Description: Performs a SW switch to a predefined output symbol. This attribute is specific to toggle enabled channels and allows switching between multiple predefined symbols. Each symbol corresponds to a different output, denoted as out_voltageY_rawN, where N is the integer value of the symbol. Writing an integer value N will select out_voltageY_rawN.